The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Emergency management of aorto-bronchial fistula after implantation of a self-expanding bronchial stent

Lookup NU author(s): T Pillay, Colin Hilton

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

We report a case of aorto-bronchial fistula 7 years after implantation of a self-expanding metal stent into the left main bronchus. The clinical presentation was characterised by left-sided chest pain, dyspnea and a single bout of haemoptysis. The fistula was surgically managed by aortic resection and primary repair of the aorta, and patch repair of the left main bronchus over a Polyflex covered bronchial stent. When haemoptysis occurs in a patient with a history of bronchial stent implantation, the presence of an aorto-bronchial fistula should be considered. Early diagnosis offers the only possibility of recovery through a lifesaving surgical procedure. (C) 2001 Elsevier Science B.V. All rights reserved.


Publication metadata

Author(s): Nouraei SM, Pillay T, Hilton CJ

Publication type: Article

Publication status: Published

Journal: European Journal of Cardio-Thoracic Surgery

Year: 2001

Volume: 20

Issue: 3

Pages: 642-644

ISSN (print): 1010-7940

ISSN (electronic): 1873-734X

Publisher: Oxford University Press

URL: http://dx.doi.org/10.1016/S1010-7940(01)00836-3

DOI: 10.1016/S1010-7940(01)00836-3


Altmetrics

Altmetrics provided by Altmetric


Share