Toggle Main Menu Toggle Search

Open Access padlockePrints

The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

A machine for haemodialysing very small infants

Lookup NU author(s): Dr Malcolm Coulthard, Dr Michael Keir

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

Babies weighing under 6 kg are difficult to dialyse, especially those as small as 1 kg. Peritoneal dialysis is easier than haemodialysis, but is not always possible, and clears molecules less efficiently. Two factors complicate haemodialysis. First, extracorporeal circuits are large relative to a baby's blood volume, necessitating priming with fresh or modified blood. Second, blood flow from infants' access vessels is disproportionately low ( Poiseuille's law), causing inadequate dialysis, or clotting within the circuit. These problems are minimised by using single lumen access, a very small circuit, and a reservoir syringe to separate the sampling and dialyser blood flow rates. Its manual operation is tedious, so we developed a computer-controlled, pressure-monitored machine to run it, including adjusting the blood withdrawal rate from poorly sampling lines. We have dialysed four babies weighing 0.8 - 3.4 kg, with renal failure or metabolic disorders. The circuits did not require priming. Clearances of creatinine, urea, potassium, phosphate and ammonia were mean (SD) 0.54 (0.22) ml/min using one dialyser, and 0.98 ( 0.22) ml/ min using two in parallel. Ammonia clearance in a 2.4 kg baby had a 9 h half-life. Ultrafiltration up to 45 ml/h was achieved easily. This device provided infants with immediate, effective and convenient haemodialysis, typically delivered for prolonged periods.


Publication metadata

Author(s): Everdell NL, Coulthard MG, Crosier J, Keir MJ

Publication type: Article

Publication status: Published

Journal: Pediatric Nephrology

Year: 2005

Volume: 20

Issue: 5

Pages: 636-643

ISSN (print): 0931-041X

ISSN (electronic): 1432-198X

Publisher: Springer

URL: http://dx.doi.org/10.1007/s00467-004-1785-5

DOI: 10.1007/s00467-004-1785-5


Altmetrics

Altmetrics provided by Altmetric


Share