The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Clinical evaluation of a simple uroflowmeter for categorization of maximum urinary flow rate

Lookup NU author(s): Dr Simon Pridgeon, Rob Pickard

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

Objective: To evaluate the accuracy and diagnostic usefulness of a disposable flowmeter consisting of a plastic funnel with a spout divided into three chambers. Materials and Methods: Men with lower urinary tract symptoms (LUTS) voided sequentially into a standard flowmeter and the funnel device recording maximum flow rate (Qmax ) and voided volume (V void ). The device was precalibrated such that filling of the bottom, middle and top chambers categorized maximum input flows as 10, 10-15 and > 15 ml s-1 respectively. Subjects who agreed to use the funnel device at home obtained readings of flow category and Vvoid twice daily for seven days. Results: A single office reading in 46 men using the device showed good agreement with standard measurement of Qmax for Vvoid > 150 ml (Kappa = 0.68). All 14 men whose void reached the top chamber had standard Qmax > 15 ml s-1 (PPV = 100%, NPV = 72%) whilst eight of 12 men whose void remained in the bottom chamber had standard Qmax < 10 ml s-1 (PPV = 70%, NPV = 94%). During multiple home use by 14 men the device showed moderate repeatability (Kappa = 0.58) and correctly categorized Qmax in comparison to standard measurement for 12 (87%) men. Conclusions: This study suggests that the device has sufficient accuracy and reliability for initial flow rate assessment in men with LUTS. The device can provide a single measurement or alternatively multiple home measurements to categorize men with Qmax < 15 ml s -1.


Publication metadata

Author(s): Pridgeon SW, Harding C, Newton D, Pickard RS

Publication type: Article

Publication status: Published

Journal: Indian Journal of Urology

Year: 2007

Volume: 23

Issue: 2

Pages: 114-118

Print publication date: 01/07/2007

ISSN (print): 0970-1591

ISSN (electronic): 1998-3824

URL: http://dx.doi.org/10.4103/0970-1591.32058