Toggle Main Menu Toggle Search

Open Access padlockePrints

The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Establishing ongoing quality assurance in a retinal screening programme

Lookup NU author(s): Dr Chankramath Arun, Dr Kevin Stannard, Professor Roy Taylor

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

Aim: To establish a clinically efficient, cost-effective quality assurance programme as part of a routine retinopathy screening service. Methods: The operation of a quality assurance system as part of an ongoing retinal screening service is described. A random selection of 12% of images of all people reported to have retinopathy and of 2% reported to have no retinopathy are re-graded by a consultant ophthalmologist. Entry of the two sets of data into a purpose-designed excel spreadsheet allows automated calculation of sensitivity and specificity. Results: The results of quality assurance from August 2001 to July 2003 are reported. Out of 8351 screening episodes, 498 were re-examined. Of the 62 cases identified by the ophthalmologist as having referable retinopathy, four false negatives for detection were identified. Three of these had been assigned to early re-screening by the retinal screener but were still regarded as false negative by the parameters of the quality assurance system. The sensitivity and specificity for detection of sight-threatening retinopathy were 93.5% (95% CI = 84.3-98.2%) and 97.8% (95% CI = 95.8-98.9%), respectively. Conclusion: A robust and cost-effective system has been developed to allow monitoring of performance of routine retinal screening which may be extended to meet current national recommendations. © 2006 Diabetes.


Publication metadata

Author(s): Arun CS, Young D, Batey D, Shotton M, Mitchie D, Stannard KP, Taylor R

Publication type: Article

Publication status: Published

Journal: Diabetic Medicine

Year: 2006

Volume: 23

Issue: 6

Pages: 629-634

ISSN (print): 0742-3071

ISSN (electronic): 1464-5491

Publisher: Wiley-Blackwell

URL: http://dx.doi.org/10.1111/j.1464-5491.2006.01865.x

DOI: 10.1111/j.1464-5491.2006.01865.x


Altmetrics

Altmetrics provided by Altmetric


Share