Toggle Main Menu Toggle Search

Open Access padlockePrints

The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Comparisons of platinum, gold, palladium and glassy carbon as electrode materials in the design of biosensors for glutamate

Lookup NU author(s): Dr Seung Chang, Emeritus Professor Calum McNeilORCiD

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

Four electrode materials: Pt, Au, Pd and glassy carbon (GC), were studied to investigate their suitability as substrates in the development of two different classes of glutamate biosensor. Glutamate oxidase cross-linked onto poly(o-phenylenediamine) was chosen as the type 1 biosensor (PPD/GluOx), incorporating PPD as the permselective element to detect H2O 2 directly on the electrode surface at relatively high applied potentials. GluOx and horseradish peroxidase/redox polymer modified electrodes (Os2+PVP/HRP/GluOx) that relied on enzyme-catalysed H 2O2 detection at lower applied potentials were used as type 2 biosensors. The voltammetric and amperometric responses to the enzyme signal transduction molecule, H2O2, and the archetypal interference species in biological applications, ascorbic acid, were determined on the bare and PPD/GluOx-modified surfaces. The amperometric responses of these electrodes were stable over several days of continuous recording in phosphate buffered saline (pH 7.4). The sensitivity of the type 1 biosensors to H2O2 and glutamate showed parallel trends with low limits of detection and good linearity at low concentrations: Pt>Au∼Pd≫GC. Type 2 biosensors out-performed the type 1 design for all electrode substrates, except Pt. However, the presence of the permselective PPD membrane in the type 1 biosensors, not feasible in the type 2 design, suggests that Pt/PPD/GluOx might have the best all-round characteristics for glutamate detection in biological media containing interference species such as ascorbic acid. Other points affecting a final choice of substrate should include factors such as mass production issues. © 2003 Elsevier B.V. All rights reserved.


Publication metadata

Author(s): O'Neill RD, Chang SC, Lowry JP, McNeil CJ

Publication type: Article

Publication status: Published

Journal: Biosensors and Bioelectronics

Year: 2004

Volume: 19

Issue: 11

Pages: 1521-1528

ISSN (print): 0956-5663

ISSN (electronic): 1873-4235

Publisher: Elsevier BV

URL: http://dx.doi.org/10.1016/j.bios.2003.12.004

DOI: 10.1016/j.bios.2003.12.004

PubMed id: 15093225


Altmetrics

Altmetrics provided by Altmetric


Share