The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

From field to wall: On-site ground corn-cob infill for low-cost passive thermal-comfort retrofits in rural cold-climate China

Lookup NU author(s): Di Yang, Professor Neveen Hamza, Professor Rose GilroyORCiD

Downloads


Licence

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND).


Abstract

© 2026 The AuthorsGround corn-cob infill is evaluated as a low-cost wall retrofit strategy to improve thermal performance and assess building-level impact in rural dwellings in cold-climate China. Field measurements of indoor temperature and relative humidity were conducted in ten occupied households representing five household typologies during summer and winter. Median indoor temperatures were 29.8 °C in summer and 5.5 °C in winter, with only 1.3% of winter hours meeting the GB/T 18,883–2022 comfort standard, indicating severe under-heating. The thermal transmittance of four wall configurations was determined using in-situ heat-flux measurements in accordance with ISO 9869–1. Ground corn-cob infill achieved the lowest U-value (0.981 W/(m²·K) under ΔT ≥ 10 °C), representing a 46.6% reduction relative to an unfilled hollow-brick wall. Measured U-values were implemented in calibrated building performance simulation models to assess envelope-only retrofit scenarios. Under free-running conditions, none of the configurations met the national winter comfort standard. However, when evaluated against a locally derived comfort range (9.9–17.5 °C), the addition of a corn-cob-infilled outer layer increased winter comfort duration by up to 197 h in multi-generational households. No improvement in summer comfort was observed under sealed conditions due to reduced nocturnal heat dissipation. The results demonstrate that finely processed corn-cob infill can substantially reduce wall heat loss and improve winter thermal conditions in low-income rural housing. However, its effectiveness is seasonally dependent and requires integration with ventilation strategies to address summer performance. The proposed retrofit offers a scalable, low-cost solution for energy-poor rural contexts using locally available agricultural residues.


Publication metadata

Author(s): Yang D, Hamza N, Gilroy R

Publication type: Article

Publication status: Published

Journal: Building and Environment

Year: 2026

Volume: 302

Online publication date: 01/06/2026

Acceptance date: 30/05/2026

Date deposited: 15/06/2026

ISSN (print): 0360-1323

ISSN (electronic): 1873-684X

Publisher: Elsevier Ltd

URL: https://doi.org/10.1016/j.buildenv.2026.114825

DOI: 10.1016/j.buildenv.2026.114825

Data Access Statement: Data will be made available on request