The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Determination and use of patient curvature correction factors by measurement in electron monitor unit calculations

Lookup NU author(s): Neil Richmond, Dr Liam Walker

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

© 2026 American Association of Medical Dosimetrists. In our department, monitor units (MU) for electron treatments are calculated using a Monte Carlo algorithm in the RayStation treatment planning system and independently checked using RadCalc software. An audit found that 22 of 50 independent checks failed the ± 5% local tolerance level. One of the causes for the discrepancy was thought to be that the RadCalc calculation takes no account of the patient surface curvature. Three-dimensional printed moulds were used to create wax “domes” and “bowls” with curvatures ranging from +0.33 cm−1 to −0.13 cm−1. The dose per MU delivered at dmax, under the wax phantoms, to a calibrated NACP type chamber was determined by measurement. The fields were delivered using 6 to 18 MeV electrons from a Varian TrueBeam linac. The measured data shows that the dose varies linearly, for a given electron energy, with the curvature of the wax mould. This information was used to create a set of curvature correction factors to be applied to the 50 independent MU checks. When the appropriate correction factor was applied to the RadCalc MU only 3 of the 50 calculations were beyond the tolerance level, improving agreement and reducing the number of out of tolerance results.


Publication metadata

Author(s): Richmond N, Chester K, Walker L

Publication type: Article

Publication status: Published

Journal: Medical Dosimetry

Year: 2026

Pages: Epub ahead of print

Online publication date: 22/04/2026

Acceptance date: 15/03/2026

ISSN (print): 0958-3947

ISSN (electronic): 1873-4022

Publisher: Elsevier Inc.

URL: https://doi.org/10.1016/j.meddos.2026.03.007

DOI: 10.1016/j.meddos.2026.03.007


Altmetrics

Altmetrics provided by Altmetric


Share