The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Performance evaluation of a 400 kW vanadium redox flow battery system incorporating high-voltage direct-current series connected stacks: Experimental and modeling insights

Lookup NU author(s): Ron Koh, Dr Anurag SharmaORCiD, Dr Khalid AbidiORCiD, Dr Jun Jie ChongORCiD

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

© 2026 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.Vanadium redox flow batteries (VRFBs) are designed for grid-scale energy storage due to their decoupled power-energy configuration, long service life, and inherently safe aqueous electrolyte system. In this study, a 400 kW/1600 kWh VRFB comprising 558 series-connected cells is evaluated. The highly serialized configuration provides a direct stack output of approximately 850 V. However, most publicly available studies have not analyzed highly series-connected systems with multiple shared electrolyte pathways, which can induce large shunt currents that reduce coulombic efficiency. In this work, a highly series-connected system is analyzed with and without shunt-current inhibitors to analyze their effectiveness in reducing shunt currents in highly series-connected VRFB systems.Simulation results, validated using operational data from the 400 kW system, show that the inhibitors reduce the shunt-current magnitude (A⋅[jls-end-space/]cell−1) by approximately 80% and decrease the charging shunt current to cell current ratio from 2% to 0.5%. Analysis of loss distribution indicates that cell-manifold pathways contribute roughly 63% of total shunt-current losses, identifying the cell-manifold region as the primary target for further inhibitor optimization. Our findings provide design guidance for improving efficiency and scalability in high-voltage VRFB architectures.


Publication metadata

Author(s): Koh R, Bhattarai A, Kumar A, Ghimire PC, Ranjan R, Sahu A, Yong W, Sharma A, Abidi K, Chong J

Publication type: Article

Publication status: Published

Journal: Journal of Power Sources

Year: 2026

Volume: 670

Print publication date: 01/04/2026

Online publication date: 11/02/2026

Acceptance date: 20/01/2026

ISSN (print): 0378-7753

ISSN (electronic): 1873-2755

Publisher: Elsevier B.V.

URL: https://doi.org/10.1016/j.jpowsour.2026.239402

DOI: 10.1016/j.jpowsour.2026.239402


Altmetrics

Altmetrics provided by Altmetric


Share