The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Reliability-Security Trade-Off for Distributed Reactive Power Control in Transactive Grid

Lookup NU author(s): Dr Muhammad Ramadan SaifuddinORCiD

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

Under the trend of deregulated Volt/VAR ancillary service market, power distribution grid (PDG) is seeing a growing demand for personally owned distributed energy resources (DERs) installed behind-the-meter as value adding participants. A trustworthy cyber-physical network thus becomes essential for coordinating these decentralized participants (e.g., by aggregators) in supporting Volt/VAR optimisation, a critical conservation voltage reduction (CVR) operation. Meanwhile, oversized inverters, which reserve a larger reactive power (VAR) capacity than needed for real power generation, provide incentive payouts during market participation; they are thus likely to be adopted by future customers. This adoption, as our findings show however, inaugurates a fundamental reliability-security tradeoff, when the surplus VAR capacity, in the wrong hands of cyber attackers, can become a stronger weapon for damaging voltage control as a malicious intent. This paper presents novel analysis of key mechanisms and impacts of a class of data integrity attacks against voltage control during CVR. Evaluation results using a realistic 118-bus test system show that tampering with Volt/VAR control in prosumer-side DER and metering devices, which service D-STATCOM, can cause harmful power quality degradation (e.g., excessive voltage dips) or even power interruption. The results also quantify (i) trade-offs between better Volt/VAR control (i.e., increased reliability) and heightened potency of data integrity attacks (i.e. weakened security) under DER inverter oversizing; and (ii) impacts of these attacks under salient global trends such as increasing DER adoption.


Publication metadata

Author(s): Saifuddin R, Yau D, Lou X

Publication type: Conference Proceedings (inc. Abstract)

Publication status: Published

Conference Name: 2021 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm)

Year of Conference: 2021

Pages: 57-63

Print publication date: 13/12/2016

Online publication date: 13/12/2021

Acceptance date: 13/12/2021

Publisher: IEEE

URL: https://doi.org/10.1109/SmartGridComm51999.2021.9632313

DOI: 10.1109/SmartGridComm51999.2021.9632313

Library holdings: Search Newcastle University Library for this item

ISBN: 9781665430449


Share