The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Can early phase cardiac [123I]mIBG images be used to diagnose Lewy body disease?

Lookup NU author(s): Dr Gemma RobertsORCiD, Dr Joseph Kane, Dr James LloydORCiD, Dr Michael FirbankORCiD, Dr Paul DonaghyORCiD, Dr George Petrides, Professor John-Paul TaylorORCiD, Professor John O'Brien, Professor Alan ThomasORCiD

Downloads


Licence

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND).


Abstract

Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved. Purpose Some studies have suggested that cardiac [123I]metaiodobenzylguanidine images obtained 15-20 min after tracer administration are as accurate for dementia with Lewy bodies (DLB) diagnosis as standard images acquired after a delay of 3-4 h; some suggest delayed imaging is preferable. We compare early and delayed heart-to-mediastinum ratios (HMR) in a well-characterised research dataset and make recommendations for clinical practice. Methods Images were acquired using a Siemens gamma camera with medium energy collimators. Early images were obtained at 20 min and delayed at 4 h (± 30) min. In total 167 pairs of images were reviewed: 30 controls, 39 people with dementia and 98 with mild cognitive impairment. HMR normal cutoff values derived from control data were ≥2.10 for early imaging and ≥1.85 for delayed. Results HMR tended to drop between early and delayed for abnormal images, but increase for normal images. Histograms of early and delayed HMR showed a slightly better separation of results into two groups for delayed imaging. Accuracy results were slightly higher for delayed imaging than early imaging (73 vs. 77%), sensitivity 63 vs. 65% and specificity 82 vs. 88%. However, this was not statistically significant-in total only 8/167 (5%) of scans changed designation between early and delayed imaging. Conclusion We suggest that a delayed image could be acquired only if the early result is borderline. This removes the need for delayed imaging in about 70% of patients. Adopting this protocol in clinical practice would reduce the time most patients have to wait and could free up scanner time.


Publication metadata

Author(s): Roberts G, Kane JPM, Lloyd J, Firbank M, Donaghy PC, Petrides GS, Taylor J-P, O'Brien J, Thomas AJ

Publication type: Article

Publication status: Published

Journal: Nuclear Medicine Communications

Year: 2022

Volume: 43

Issue: 7

Pages: 770-777

Print publication date: 01/07/2022

Online publication date: 20/05/2022

Acceptance date: 12/04/2022

Date deposited: 08/09/2022

ISSN (print): 0143-3636

ISSN (electronic): 1473-5628

Publisher: Lippincott Williams and Wilkins

URL: https://doi.org/10.1097/MNM.0000000000001581

DOI: 10.1097/MNM.0000000000001581

PubMed id: 35603421


Altmetrics

Altmetrics provided by Altmetric


Funding

Funder referenceFunder name
ARUK-PG2015-13Alzheimer`s Research UK
NIHR Newcastle Biomedical Research Centre

Share