Toggle Main Menu Toggle Search

Open Access padlockePrints

The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

On-site geometric calibration of RPAS mounted sensors for SfM photogrammetric geomorphological surveys

Lookup NU author(s): Dr Johannes Senn, Professor Jon MillsORCiD, Professor Claire WalshORCiD, Dr Maria-Valasia PeppaORCiD

Downloads


Licence

This work is licensed under a Creative Commons Attribution 4.0 International License (CC BY 4.0).


Abstract

The application of structure from motion (SfM) photogrammetry for digital elevationmodel (DEM) and orthophoto generation from visible imagery enjoys ever-growingpopularity in geomorphological research. Photogrammetry experts, however, urgethat a rigorous approach is a prerequisite for reliable results—a requirement that mayconflict with real-world survey. We present a method that unites the two disciplines,using the example of a challenging SfM photogrammetric survey at a Scottish river.Using simultaneous geometric pre-calibration of a multi-sensor remotely piloted air-craft system (RPAS), the method facilitates time-efficient topography mapping andthe integration of other wavelengths to create orthophotos providing additional sur-face information. The approach utilizes an on-site 3D structure—for example, a build-ing, as calibration object, by extracting coordinates of natural features from lidarscans and sensor imagery. We assess the workflow with specialized calibration soft-ware (VMS) and widely applied commercial SfM photogrammetric software (AM),using a DJI Phantom optical and a Workswell thermal sensor. We achieved calibra-tion accuracies below one-third (optical) and one-quarter (thermal) of a pixel. Subse-quently, we transfer the sensor parameters to pre-calibrate the SfM application andcompare the results to a self-calibrated workflow. In a systematic experiment usingthe optical river survey dataset, we assess the effectiveness of pre-calibration,oblique imagery, scale variation and masking to mitigate systematic DEM errors.Opposing trends show between the calibration strategies. Decreasing network com-plexity (i.e., flying heights/view angles) improves pre-calibrated but compromisesself-calibrated scenarios. Pre-calibrating (VMS) imagery from a single height (30 mnadir) yielded the best results. This finding could have implications for geomorpho-logical surveys, in which single-scale datasets are widespread practice, despite theliterature’s urge towards more complex imaging networks. The self-calibrated resultslegitimise this insistence: The same dataset resulted in pronounced dome-shapedDEM distortion, indicating systematic errors, whereas additional flying heights andangles significantly improved the results.


Publication metadata

Author(s): Senn JA, Mills J, Walsh CL, Addy S, Peppa M-V

Publication type: Article

Publication status: Published

Journal: Earth Surface Processes and Landforms

Year: 2022

Volume: 47

Issue: 6

Pages: 1615-1634

Print publication date: 01/05/2022

Online publication date: 07/02/2022

Acceptance date: 25/01/2022

Date deposited: 09/03/2022

ISSN (print): 0197-9337

ISSN (electronic): 1096-9837

Publisher: John Wiley & Sons Ltd

URL: https://doi.org/10.1002/esp.5338

DOI: 10.1002/esp.5338


Altmetrics

Altmetrics provided by Altmetric


Funding

Funder referenceFunder name
EP/R010102/1

Share