The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Physiological effects of high-flow nasal cannula therapy in preterm infants

Lookup NU author(s): Dr Zheyi Liew, Dr Alan Fenton, Dr Sundeep Harigopal, Dr Saikiran Gopalakaje, Dr Malcolm BrodlieORCiD

Downloads


Licence

This work is licensed under a Creative Commons Attribution 4.0 International License (CC BY 4.0).


Abstract

© Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY. Published by BMJ.Objective: High-flow nasal cannula (HFNC) therapy is increasingly used in preterm infants despite a paucity of physiological studies. We aimed to investigate the effects of HFNC on respiratory physiology. Study design: A prospective randomised crossover study was performed enrolling clinically stable preterm infants receiving either HFNC or nasal continuous positive airway pressure (nCPAP). Infants in three current weight groups were studied: <1000 g, 1000-1500 g and >1500 g. Infants were randomised to either first receive HFNC flows 8-2 L/min and then nCPAP 6 cm H2O or nCPAP first and then HFNC flows 8-2 L/min. Nasopharyngeal end-expiratory airway pressure (pEEP), tidal volume, dead space washout by nasopharyngeal end-expiratory CO2 (pEECO2), oxygen saturation and vital signs were measured. Results: A total of 44 preterm infants, birth weights 500-1900 g, were studied. Increasing flows from 2 to 8 L/min significantly increased pEEP (mean 2.3-6.1 cm H2O) and reduced pEECO2 (mean 2.3%-0.9%). Tidal volume and transcutaneous CO2 were unchanged. Significant differences were seen between pEEP generated in open and closed mouth states across all HFNC flows (difference 0.6-2.3 cm H2O). Infants weighing <1000 g received higher pEEP at the same HFNC flow than infants weighing >1000 g. Variability of pEEP generated at HFNC flows of 6-8 L/min was greater than nCPAP (2.4-13.5 vs 3.5-9.9 cm H2O). Conclusions: HFNC therapy produces clinically significant pEEP with large variability at higher flow rates. Highest pressures were observed in infants weighing <1000 g. Flow, weight and mouth position are all important determinants of pressures generated. Reductions in pEECO2 support HFNC's role in dead space washout.


Publication metadata

Author(s): Liew Z, Fenton AC, Harigopal S, Gopalakaje S, Brodlie M, O'Brien CJ

Publication type: Article

Publication status: Published

Journal: Archives of Disease in Childhood: Fetal and Neonatal Edition

Year: 2019

Volume: 105

Issue: 1

Pages: 87-93

Print publication date: 16/12/2019

Online publication date: 23/05/2019

Acceptance date: 03/05/2019

Date deposited: 06/06/2019

ISSN (print): 1359-2998

ISSN (electronic): 1468-2052

Publisher: BMJ Publishing Group

URL: https://doi.org/10.1136/archdischild-2018-316773

DOI: 10.1136/archdischild-2018-316773


Altmetrics

Altmetrics provided by Altmetric


Funding

Funder referenceFunder name
MR/M008797/1Medical Research Council (MRC)

Share