The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Accuracy of left atrial bipolar voltages obtained by ConfiDENSE multielectrode mapping in patients with persistent atrial fibrillation

Lookup NU author(s): Dr Moloy Das, Matthew Shaw

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

© 2018 Wiley Periodicals, Inc. Introduction: The ConfiDENSE™ module (Carto3 v4) allows rapid annotation of endocardial electrograms acquired by multielectrode (ME) mapping. However, its accuracy in assessing atrial voltages is unknown. Methods and results: Two ConfiDENSE™ left atrial voltage maps were created during continuous pacing in 20 patients undergoing catheter ablation for persistent AF using a ME lasso catheter and a contact force (CF) sensing ablation catheter. The automated tissue proximity indicator (TPI) filter was then applied to the ME map to yield a TPI map. Reference maps (RM) were created offline by a blinded observer by manually assessing all points against fidelity criteria. Bipolar voltages and proportion of low voltage points (< 0.5 mV) derived from the ME, CF, and TPI maps were compared with those derived from the RM. Note that 853 ± 365 points, 252 ± 184 points, and 144 ± 73 were collected for ME, TPI, and CF maps, respectively, and 429 ± 153 points were included in the RM. Voltages with CF and TPI maps were similar to those with RM (1.57 ± 0.47 mV vs. 1.63 ± 0.31 mV, P = 0.57 and 1.50 ± 0.38 mV vs. 1.63 ± 0.31 mV, P = 0.07, respectively), whereas ME maps showed a significantly lower mean voltage (1.00 ± 0.22 mV, P < 0.001). As compared to RM maps (17 ± 8%), low voltage points were significantly overestimated by the ME maps (50 ± 9% (P < 0.001) and TPI maps (28 ± 13% (P < 0.001), but not by the CF maps (22 ± 14%, P = 0.17). Conclusion: Application of the TPI filter to ConfiDENSE maps significantly increases the quality of the voltage data, conserving a reasonable point density, but still overestimates low voltage points as compared to CF-sensing maps or maps reviewed manually.


Publication metadata

Author(s): Maille B, Das M, Hussein A, Shaw M, Chaturvedi V, Morgan M, Ronayne C, Snowdon RL, Gupta D

Publication type: Article

Publication status: Published

Journal: Journal of Cardiovascular Electrophysiology

Year: 2018

Volume: 29

Issue: 6

Pages: 881-888

Print publication date: 01/06/2018

Online publication date: 05/03/2018

Acceptance date: 20/02/2018

ISSN (print): 1045-3873

ISSN (electronic): 1540-8167

Publisher: Wiley-Blackwell Publishing Inc.

URL: https://doi.org/10.1111/jce.13472

DOI: 10.1111/jce.13472


Altmetrics

Altmetrics provided by Altmetric


Share