The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

A descriptive and broadly applicable model of therapeutic and stray absorbed dose from 6 to 25 MV photon beams

Lookup NU author(s): Dr Roger Harrison

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

© 2017 American Association of Physicists in Medicine. Purpose: To develop a simple model of therapeutic and stray absorbed dose for a variety of treatment machines and techniques without relying on proprietary machine-specific parameters. Methods: Dosimetry measurements conducted in this study and from the literature were used to develop an analytical model of absorbed dose from a variety of treatment machines and techniques in the 6 to 25 MV interval. A modified one-dimensional gamma-index analysis was performed to evaluate dosimetric accuracy of the model on an independent dataset consisting of measured dose profiles from seven treatment units spanning four manufacturers. Results: The average difference between the calculated and measured absorbed dose values was 9.9% for those datasets on which the model was trained. Additionally, these results indicate that the model can provide accurate calculations of both therapeutic and stray radiation dose from a wide variety of radiotherapy units and techniques. Conclusions: We have developed a simple analytical model of absorbed dose from external beam radiotherapy treatments in the 6 to 25 MV beam energy range. The model has been tested on measured data from multiple treatment machines and techniques, and is broadly applicable to contemporary external beam radiation therapy.


Publication metadata

Author(s): Schneider CW, Newhauser WD, Wilson LJ, Schneider U, Kaderka R, Miljanic S, Knezevic Z, Stolarcyzk L, Durante M, Harrison RM

Publication type: Article

Publication status: Published

Journal: Medical Physics

Year: 2017

Volume: 44

Issue: 7

Pages: 3805-3814

Print publication date: 07/07/2017

Online publication date: 21/04/2017

Acceptance date: 23/03/2017

ISSN (print): 0094-2405

ISSN (electronic): 2473-4209

Publisher: Wiley Blackwell

URL: https://doi.org/10.1002/mp.12286

DOI: 10.1002/mp.12286


Altmetrics

Altmetrics provided by Altmetric


Share