The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Efficacy of transscleral diode laser cyclophotocoagulation in patients with good visual acuity

Lookup NU author(s): Neeta Ray-Chaudhuri, Michael Birch

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

Purpose: To study the effect on central vision of transscleral diode laser cyclophotocoagulation (TSDLC) for the reduction of intraocular pressure (IOP) in patients with visual acuity (VA) better than 6/18.Methods: Retrospective chart review was conducted of patients undergoing cyclophotocoagulation between 2000 and 2008. Patients who underwent TSDLC with VA of 6/18 or better and at least 24 months follow-up were included. Primary outcome was decrease of 2 or more lines at 24 months. Secondary outcome was IOP control with or without treatment.Results: A total of 46 eyes of 44 patients were included with VA ranging from 6/18 to 6/5 (median VA 6/12). Mean IOP was 24 mm Hg (range 12-35). A mean of 1.3 treatments were given per eye, with 12 eyes (26%) requiring retreatment. At 24 months, the median VA was 6/18 (range light perception-6/5). Eighteen eyes (39.1%) retained the same VA, 35 eyes (76.1%) retained VA of 6/18 or better, in 7 eyes (19.4%) VA was <6/60. Loss of >= 2 lines was recorded in 11 eyes (23.9%), and loss of 1 line in 13 eyes (28.3%). Mean IOP at 24 months was 17.2 mm Hg (range 12-28). Thirty-nine (84.8%) patients had IOP <= 21 mm Hg.Conclusions: This study suggests a role of TSDLC as an effective, safe, and rapid method of treatment in patients with good vision over a 24-month period. The loss of VA in some patients is similar to previously reported studies in patients having cyclodiode, trabeculectomy, or tube surgery.


Publication metadata

Author(s): Ghosh S, Manvikar S, Ray-Chaudhuri N, Birch M

Publication type: Article

Publication status: Published

Journal: European Journal of Ophthalmology

Year: 2014

Volume: 24

Issue: 3

Pages: 375-381

Print publication date: 28/03/2014

Online publication date: 12/11/2014

Acceptance date: 14/10/2014

ISSN (print): 1120-6721

ISSN (electronic): 1724-6016

Publisher: Wichtig Publishing

URL: http://dx.doi.org/10.5301/ejo.5000389

DOI: 10.5301/ejo.5000389

PubMed id: 24242221


Altmetrics

Altmetrics provided by Altmetric


Share