The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Calculating stable reference potentials for measuring ECG wave amplitudes across a range of heart rates

Lookup NU author(s): Wenfeng Duan, Dr Ding Chang Zheng, Dr Philip Langley, Emeritus Professor Alan MurrayORCiD

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

The UP segment is the normal isoelectric reference level for ECG wave amplitude measurements but becomes obscured at high heart rates. The aim was to identify alternative reference levels suitable for use across a wide range of heart rates. 12-lead ECGs were recorded from 10 healthy subjects before and immediately following exercise. Amplitudes of the UP segment, Q wave, end of T wave (T-end) and zero voltage level, all relative to PQ level were measured from V3. The performances of beat waveform averaging (AvgBeat) and mathematical averaging of separate beat measurements (AvgVal) on reducing the influence of noise and measurement errors were compared.Due to merging of P and U waves at high heart rates, the UP segment amplitude was measureable in only approximately 71% when the heart rate was over 120 b/min. Both the UP segment amplitude and T-end amplitude tended to be overestimated at high heart rates. The standard deviations (SDs) were 0.02, 0.005, 0.021 and 0.016 mV for UP segment, Q wave, end of T wave (T-end) and zero voltage levels over the range of heart rates when using AvgVal. The SDs of amplitudes measured by AvgBeat and AvgVal methods were significantly lower than those measured from single beats (p < 0.05) for almost all features. Generally, these two methods achieved comparable performance on reducing measurement variability.


Publication metadata

Author(s): Duan W, Zheng D, Langley P, Murray A

Publication type: Conference Proceedings (inc. Abstract)

Publication status: Published

Conference Name: Computing in Cardiology

Year of Conference: 2012

Pages: 57-60

ISSN: 2325-8861

Publisher: IEEE

URL: http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6420329&isnumber=6420314

Library holdings: Search Newcastle University Library for this item

ISBN: 9781467320764


Share