Toggle Main Menu Toggle Search

Open Access padlockePrints

The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Model based evaluation of the effect of pH and electrode geometry on microbial fuel cell performance

Lookup NU author(s): Dr Cristian Picioreanu, Professor Thomas CurtisORCiD, Emeritus Professor Keith Scott

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

A mathematical model for microbial fuel cells (MFC) which integrates macro-scale time-dependent mass balances for solutes and biomass in the anodic liquid with a micro-scale individual-based two-dimensional biofilm model is developed. Computational fluid dynamics and Nernst-Plank mass and charge balances with diffusion, electromigration, convection and electroneutrality in the biofilm are combined to calculate spatial pH distribution and solutes speciation. Soluble redox mediators are the electron shuttle between microbial cells and the electrode. The model describes the generally observed variations of pH, solute concentrations and electrical current produced over time from electroactive biofilms. Numerical simulations also show the effect of bicarbonate buffer and mass transfer through the proton exchange membrane on the microbial population within a mixed anaerobic digestion sludge consortium of methanogenic and electrogenic microorganisms. In addition, the new modeling approach opens the way to study the influence of fluid flow and any two- or three-dimensional biofilm and electrode geometry on the MFC output parameters. Hydrodynamic calculations show that porous bio-electrodes with greater specific surface area do not necessarily produce more current, as long as convection through the pores is absent. An innovative model solution strategy combines in a very efficient and flexible way MATLAB, COMSOL finite element and Java codes. © 2009 Elsevier B.V. All rights reserved.


Publication metadata

Author(s): Picioreanu C, van Loosdrecht M, Curtis T, Scott K

Publication type: Article

Publication status: Published

Journal: Bioelectrochemistry

Year: 2010

Volume: 78

Issue: 1

Pages: 8-24

ISSN (print): 1567-5394

ISSN (electronic): 1878-562X

Publisher: Elsevier BV

URL: http://dx.doi.org/10.1016/j.bioelechem.2009.04.009

DOI: 10.1016/j.bioelechem.2009.04.009


Altmetrics

Altmetrics provided by Altmetric


Share